Exploring Unified Diagnostic Services with uds-zoo

29 October 2021 at 14:00

uds-zoo is a project created by Chris Bellows and Tom Steele at Atredis Partners.

Today we are releasing a new project that will be useful for learning and exploration of attacking and defending automotive targets, specifically Unified Diagnostic Services (UDS/ISO-14229).

There are many resources (books/blogs/papers) that can get you started down the path of learning to interrogate automotive systems. These typically focus on the controller area network (CAN) bus as the target. It is easy to follow along using an inexpensive USB adapter and (if you have the stomach for it) your vehicle, or alternatively a simulator. In contrast, UDS is usually only given a cursory overview. Most sources focus on conducting discovery of servers and services on the network, with examples interacting with a handful of services.

While it is possible for someone to follow along on their own vehicle, executing discovery and enumeration of UDS services (which is a great learning exercise), you are not guaranteed to run into a vulnerability or misconfiguration. For example, on a secured device most interesting services require the client to establish a non-default session and successfully authenticate as seen in the following table:

It is worth noting that the UDS specification (ISO-14229) is intended to be a guide and leaves the underlying implementations up to the developer, so the items marked with * may or may not be accessible depending on the service implementation or request parameters.

Besides using your own vehicle, the other option that is available would be to buy an engine control unit (ECU) to test outside of a car directly. This option is much cheaper than purchasing an entire car, except it still requires providing power as well as any signals the device may require to enter a running state. You may ultimately end up in the same situation where the device has been designed to require authentication to access most services.

These pain-points led to the idea of creating a framework designed to allow someone to explore example UDS servers with common vulnerabilities. After some internal brainstorming on how to implement the framework, we decided to abstract away all of the underlying layers (CAN/ISO-TP) and emulate only the UDS application layer. By only emulating the application layer, the tool is not tied to a specific platform and does not require the user to setup or configure system interfaces or drivers (CAN/ISO-TP).

The application is designed to be extensible and includes a handful of example β€œlevels” that provide a capture-the-flag style experience. In addition to the example levels, a bare-bones example level is provided to get you started designing your own. By default the application provides its own interface to interact with and complete the included levels that is accessible using a web browser:

Snazzy Web -1.0 Interface

The framework and associated application server is written in Go, and we have provided Docker tooling for convenience.

For those who would rather have a more realistic experience, we also created a small Python program (isotp_gateway) that that will expose the challenges over a virtual can interface:

$ python gateway.py start               
starting thread for id: 0x01 level: Level1 rxid: 0x01 txid: 0x90
starting thread for id: 0x02 level: Level2 rxid: 0x02 txid: 0x90
starting thread for id: 0x03 level: Level3 rxid: 0x03 txid: 0x90
starting thread for id: 0x04 level: Level4 rxid: 0x04 txid: 0x90
starting thread for id: 0x05 level: Level5 rxid: 0x05 txid: 0x90

After starting the gateway, each level will be accessible over the virtual can interface and can be interacted with using whatever tool you’d like. For instance, using isotpsend to interact with Level1:

$ echo 22 13 37 | isotpsend -s 0x01 -d 0x90 vcan0

We look forward to community contributions and implementing additional exercises in the future.

Source of uds-zoo and additional documentation can be found at GitHub: https://github.com/atredispartners/uds-zoo

Exploring Unified Diagnostic Services with uds-zoo

GE Healthcare MAC 5500 Vulnerabilities

15 May 2018 at 16:29
A GE Healthcare MAC 5500

A GE Healthcare MAC 5500

A few months ago, Atredis Partners had an opportunity to look at the GE Healthcare MAC5500 Electrocardiography device. This device connects to a hospital network to transfer reports to a centralized server, simplifying the workflow for EKG measurements. To facilitate transfer of this data, GE Healthcare offers MobileLink, a WiFi enabled solution for collecting measurements.

The MAC5500 device does not directly connect to a WiFi network. Instead, it uses a serial to WiFi bridge made by Silex Technology. Two models of this bridge are supported by MobileLink: the SDS-500 and SD-320AN. Atredis Partners identified vulnerabilities in these devices that allow for authentication bypass and remote command execution. These vulnerabilities resulted in ICS-CERT advisory ICSMA-18-128-01. Atredis Partners disclosed these vulnerabilities according to our disclosure policy. Silex and GE Healthcare have provided a firmware update which resolves the code execution flaw and updated their documentation for the authentication bypass issue.

SDS-500 Authentication Bypass (CVE-2018-6020)

The first vulnerability is an authentication bypass for the SDS-500 device. The SDS-500 device uses bearer token authentication to validate that a user has logged in and has access to a given resource.Β 

The check for this token is only performed for HTTP GET requests. HTTP POST requests, which are used to change device settings, are allowed without the token. The device administrator can configure an "update" password to force authentication of POST requests, but this feature is disabled by default.

By performing a POST request, an attacker can change any device setting. This includes the ability to change the device password. In a clinical environment, this may lead to a loss of availability if the device's parameters are modified.

SD-320AN Command Injection (CVE-2018-6021)

The SD-320AN is a newer serial to WiFi bridge made by Silex, and is replacing the SDS-500 for some MobileLink applications. Unlike the older SDS-500, the SD-320AN runs a Linux based operating system.

The SD-320AN is configured via a web interface, which is implemented by a CGI application written in C. In reviewing the application, multiple calls to system() were identified. A command injection vulnerability was found in one of these calls.

The SD-320AN firmware update package was found on the Silex website. This update package is a ZIP file that contains a firmware image named "SD-320.bin". Running the binwalk utility on this file indicates that it contains a bzip2-compressed Linux filesystem starting at offset zero.Β 

Output of Binwalk for Firmware Image

Output of Binwalk for Firmware Image

The CGI application is a 32-bit ARM executable located at /usr/share/www/ssi. This executable was loaded into IDA Pro and all references to the system() function were examined.

Vulnerable Call to system()

Vulnerable Call to system()

In one instance, the system() function is used to set the PIN code for Wi-Fi Protected Setup (WPS) using the the WL_PINCODE_ENRO POST parameter. This value is automatically generated by the client-side Javascript in the web application and submitted in the POST request to change this setting. An attacker can send an arbitrary value for this parameter, which poisons the parameters to the system() call, allowing remote command execution on the SD-320AN.

Command Injection Request

Command Injection Request

Command Injection Response

Command Injection Response

Conclusions

Medical devices with network connectivity pose a risk to hospital infrastructure. Security requirements for these devices are minimal and security may not be a high priority to the manufacturer. Third-party components such as the Silex bridges discussed in this article present an additional challenge to OEMs.

While the vulnerabilities discussed in this article do not pose a risk to human life, they may allow an attacker to gain persistence in a medical network. Since the vulnerabilities are relatively simple, they may also be abused in a botnet attack similar to Mirai.

Finally, command injection attacks are far too common on these types of devices. Whenever possible, calls to system() should be avoided and instead the execve() function should be used with constant executable paths. While parameter injection attacks are still possible with execve(), this change would prevent many common command injection attacks and would have avoided the vulnerability presented here.

Atredis Partners would like to thank GE Healthcare for their prompt response to our advisory and to Silex Technology for confirming and responding to the reported issues.

GE Healthcare MAC 5500 Vulnerabilities

  • There are no more articles
❌